The CTLG2.5 is a triple level Terminal Blockwith an additional connection for earthing cables.This separate connection point is appropriatelyidentified by the green - yellow imprint on its top.This Terminal Block is an ideal choice formotor, sensor, actuator and initiator connections.

TECHNICAL DATA
Rated Voltage 440 V
Rated Current 24 A
Tightening Torque 0.4 Nm
Housing MaterialPolyamide
Product FunctionTriple Level
Wire Entry OrientationSide Entry
Mounting PossibilityDIN 35/DIN 35-15 Rail
Screw SizeM2.5
Operated byScrewdriver
Rated Surge Voltage6 KV
Pollution Degree3
CONNECTION DATA
Conductor Cross Section Stranded min.0.2 mm²
Conductor Cross Section Stranded max.2.5 mm²
Conductor Cross Section AWG/Kcmil min24 AWG
Conductor Cross Section AWG/Kcmil max12 AWG
Conductor Cross Section Stranded with Ferrule/Lug min0.2 mm²
Conductor Cross Section Stranded with Ferrule/Lug max2.5 mm²
2 Conductors with same Cross Section Stranded min2.5 mm²
2 Conductor with same Cross Section Stranded max1.5 mm²
Conductor Cross Section Solid min0.2 mm²
Conductor Cross Section Solid max4 mm²
2 Conductors with same Cross Section Stranded with TWIN Ferrule/Lug min0.2 mm²
2 Conductor with same Cross Section Stranded with TWIN Ferrule/Lug max1.5 mm²
Stripping Length9 mm
Internal Cylindrical GuageA3
DIMENSIONS
Height with DIN 35 x 15 mm rail 74 mm
Height with DIN 35 x 7.5 mm rail 66 mm
Length 87.5 mm
Width (Thickness)6 mm
ORDERING INFORMATION
CAT. NO.DESCRIPTIONSTD. PACK
CTLG2.52.5 sq.mm Triple Level with ground Terminal Block in Grey colour20
ACCESSORIES
IMAGES
CAT. NO. DESCRIPTION STD. PACK
CA701
CA701-1M Din 35 Rail unslotted 1 meter 50
CA701-2M Din 35 Rail unslotted 2 meter 50
CA701-2M-S Din 35 Rail slotted 2 meter 50
CA701-1M-S Din 35 Rail slotted 1 meter 50
CA701-15
CA701-15-1M Din 35 Rail 15 deep unslotted 1 meter 50
CA701-15-1M-S Din 35 Rail 15 deep slotted 1 meter 50
CA701-15-2M Din 35 Rail 15 deep unslotted 2 meter 50
CA701-15-2M-S Din 35 Rail 15 deep slotted 2 meter 50
CA202
CA202 End Clamp in Polyamide suitable for Din 35 / Din 35-15 Rails 25
CA702
CA702 End Clamp in Polyamide 66 suitable for Din 32 / Din 35 / Din 35-15 Rails 50
CA802
CA802 End Clamp in Polyamide suitable for Din 35 / Din 35-15 Rails 50
EPCTLG2.5
EPCTLG2.5 End Plate in Grey colour suitable for CTLG2.5 / CTLG2.5(E)MOV Terminal Blocks 50
CA627/2
CA627/2 Preassembled Internal Shorting Link Assemblies with 2 poles 100
CA627/3 Preassembled Internal Shorting Link Assemblies with 3 poles 100
CA627/4 Preassembled Internal Shorting Link Assemblies with 4 poles 100
CA627/10 Preassembled Internal Shorting Link Assemblies with 4 poles 10
CA647/2
CA647/2 Insulated Pre assembled Shorting Link for 2 way shorting suitable for CDLG2.5 / CTLG2.5 Terminal Blocks. 100
CA647/3 Insulated Pre assembled Shorting Link for 3 way shorting suitable for CDLG2.5 / CTLG2.5 Terminal Blocks. 100
CA647/4 Insulated Pre assembled Shorting Link for 4 way shorting suitable for CDLG2.5 / CTLG2.5 Terminal Blocks. 100
CA647/10 Insulated Pre assembled Shorting Link for 10 way shorting suitable for CDLG2.5 / CTLG2.5 Terminal Blocks. 10
CA715/2
CA715/2 External Comb Type Shorting Link available in 2 Pole 100
CA715/3 External Comb Type Shorting Link available in 3 Pole 100
CA715/4 External Comb Type Shorting Link available in 4 Pole 100
CA715/10 External Comb Type Shorting Link available in 10 Pole 20
CA703/1
CA703/1 Permanent Shorting Link for 2 way shorting 100
CA704/1 Permanent Shorting Link for 3 way shorting 100
CA705/1 Permanent Shorting Link for 4 way shorting 100
CA732/10 Permanent Shorting Link for 10 way shorting 100
CA732/10-A Permanent Shorting Link (Breakable) for 10 way shorting 100
CA732/100 Permanent Shorting Link for 100 way shorting 100
CA611/S/Q
CA611/S/Q Shorting Sleeve and Screw 100
CA509/K2G
CA509/K2G Marking Tag Blank suitable for CDLG2.5 / CTLG2.5 / CTLG2.5(E)MOV / ADLG2.5 / ATL2.5 / ATL2.5H / ATLG2.5 Terminal Blocks 100
CA509/K2G/H Marking Tag with Horizontal printing suitable for CDLG2.5 / CTLG2.5 / CTLG2.5(E)MOV Terminal Blocks 100
CA509/K2G/V Marking Tag with Vertical printing suitable for CDLG2.5 / CTLG2.5 / CTLG2.5(E)MOV Terminal Blocks 100
CA707/TS/01
CA707/TS/01 Test Socket Suitable for CTS2.5UN / CTS2.5UE / CTS4UN / CTC4U / CMB4 / CTLG2.5 / CTL2.5U / CTL2.5UH / ODL4U / ODL4UA / CDLG2.5 / CMC1-2 / CMC2-2 Terminal Blocks. 100
SCS0.5/3AC
SCS0.5/3 Electricians Screwdriver for slotted screws 10
APPROVALS
  • NOTES
    The Rated current is with the use of copper (Cu) conductor/Wire
    Home » Products » Terminal Blocks & Connectors » Din Rail Terminal Blocks » CTS Series Screw Clamp Terminal Blocks » Multiple Level »
    Home » Products » Terminal Blocks & Connectors » Din Rail Terminal Blocks » CTS Series Screw Clamp Terminal Blocks » Multiple Level »
    CTLG2.5
    Share
    
CTLG2.5
    Three Level + Ground Feed through Terminal block

    The CTLG2.5 is a triple level Terminal Blockwith an additional connection for earthing cables.This separate connection point is appropriatelyidentified by the green - yellow imprint on its top.This Terminal Block is an ideal choice formotor, sensor, actuator and initiator connections.

    TECHNICAL DATA

    TECHNICAL DATA
    Rated Voltage 440 V
    Rated Current 24 A
    Tightening Torque 0.4 Nm
    Housing MaterialPolyamide
    Product FunctionTriple Level
    Wire Entry OrientationSide Entry
    Mounting PossibilityDIN 35/DIN 35-15 Rail
    Screw SizeM2.5
    Operated byScrewdriver
    Rated Surge Voltage6 KV
    Pollution Degree3

    CONNECTION DATA

    CONNECTION DATA
    Conductor Cross Section Stranded min.0.2 mm²
    Conductor Cross Section Stranded max.2.5 mm²
    Conductor Cross Section AWG/Kcmil min24 AWG
    Conductor Cross Section AWG/Kcmil max12 AWG
    Conductor Cross Section Stranded with Ferrule/Lug min0.2 mm²
    Conductor Cross Section Stranded with Ferrule/Lug max2.5 mm²
    2 Conductors with same Cross Section Stranded min2.5 mm²
    2 Conductor with same Cross Section Stranded max1.5 mm²
    Conductor Cross Section Solid min0.2 mm²
    Conductor Cross Section Solid max4 mm²
    2 Conductors with same Cross Section Stranded with TWIN Ferrule/Lug min0.2 mm²
    2 Conductor with same Cross Section Stranded with TWIN Ferrule/Lug max1.5 mm²
    Stripping Length9 mm
    Internal Cylindrical GuageA3

    DIMENSIONS

    DIMENSIONS
    Height with DIN 35 x 15 mm rail 74 mm
    Height with DIN 35 x 7.5 mm rail 66 mm
    Length 87.5 mm
    Width (Thickness)6 mm

    DIODE SPECIFICATIONS

    SURGE SUPRESSOR SPECIFICATIONS

    FUSE SPECIFICATIONS

    ORDERING INFORMATION

    ORDERING INFORMATION
    CAT. NO.DESCRIPTIONSTD. PACK
    CTLG2.52.5 sq.mm Triple Level with ground Terminal Block in Grey colour20

    ACCESSORIES

    ACCESSORIES
    IMAGES
    CAT. NO. DESCRIPTION STD. PACK
    CA701
    CA701-1M Din 35 Rail unslotted 1 meter 50
    CA701-2M Din 35 Rail unslotted 2 meter 50
    CA701-2M-S Din 35 Rail slotted 2 meter 50
    CA701-1M-S Din 35 Rail slotted 1 meter 50
    CA701-15
    CA701-15-1M Din 35 Rail 15 deep unslotted 1 meter 50
    CA701-15-1M-S Din 35 Rail 15 deep slotted 1 meter 50
    CA701-15-2M Din 35 Rail 15 deep unslotted 2 meter 50
    CA701-15-2M-S Din 35 Rail 15 deep slotted 2 meter 50
    CA202
    CA202 End Clamp in Polyamide suitable for Din 35 / Din 35-15 Rails 25
    CA702
    CA702 End Clamp in Polyamide 66 suitable for Din 32 / Din 35 / Din 35-15 Rails 50
    CA802
    CA802 End Clamp in Polyamide suitable for Din 35 / Din 35-15 Rails 50
    EPCTLG2.5
    EPCTLG2.5 End Plate in Grey colour suitable for CTLG2.5 / CTLG2.5(E)MOV Terminal Blocks 50
    CA627/2
    CA627/2 Preassembled Internal Shorting Link Assemblies with 2 poles 100
    CA627/3 Preassembled Internal Shorting Link Assemblies with 3 poles 100
    CA627/4 Preassembled Internal Shorting Link Assemblies with 4 poles 100
    CA627/10 Preassembled Internal Shorting Link Assemblies with 4 poles 10
    CA647/2
    CA647/2 Insulated Pre assembled Shorting Link for 2 way shorting suitable for CDLG2.5 / CTLG2.5 Terminal Blocks. 100
    CA647/3 Insulated Pre assembled Shorting Link for 3 way shorting suitable for CDLG2.5 / CTLG2.5 Terminal Blocks. 100
    CA647/4 Insulated Pre assembled Shorting Link for 4 way shorting suitable for CDLG2.5 / CTLG2.5 Terminal Blocks. 100
    CA647/10 Insulated Pre assembled Shorting Link for 10 way shorting suitable for CDLG2.5 / CTLG2.5 Terminal Blocks. 10
    CA715/2
    CA715/2 External Comb Type Shorting Link available in 2 Pole 100
    CA715/3 External Comb Type Shorting Link available in 3 Pole 100
    CA715/4 External Comb Type Shorting Link available in 4 Pole 100
    CA715/10 External Comb Type Shorting Link available in 10 Pole 20
    CA703/1
    CA703/1 Permanent Shorting Link for 2 way shorting 100
    CA704/1 Permanent Shorting Link for 3 way shorting 100
    CA705/1 Permanent Shorting Link for 4 way shorting 100
    CA732/10 Permanent Shorting Link for 10 way shorting 100
    CA732/10-A Permanent Shorting Link (Breakable) for 10 way shorting 100
    CA732/100 Permanent Shorting Link for 100 way shorting 100
    CA611/S/Q
    CA611/S/Q Shorting Sleeve and Screw 100
    CA509/K2G
    CA509/K2G Marking Tag Blank suitable for CDLG2.5 / CTLG2.5 / CTLG2.5(E)MOV / ADLG2.5 / ATL2.5 / ATL2.5H / ATLG2.5 Terminal Blocks 100
    CA509/K2G/H Marking Tag with Horizontal printing suitable for CDLG2.5 / CTLG2.5 / CTLG2.5(E)MOV Terminal Blocks 100
    CA509/K2G/V Marking Tag with Vertical printing suitable for CDLG2.5 / CTLG2.5 / CTLG2.5(E)MOV Terminal Blocks 100
    CA707/TS/01
    CA707/TS/01 Test Socket Suitable for CTS2.5UN / CTS2.5UE / CTS4UN / CTC4U / CMB4 / CTLG2.5 / CTL2.5U / CTL2.5UH / ODL4U / ODL4UA / CDLG2.5 / CMC1-2 / CMC2-2 Terminal Blocks. 100
    SCS0.5/3AC
    SCS0.5/3 Electricians Screwdriver for slotted screws 10

    NOTES

    NOTES
    The Rated current is with the use of copper (Cu) conductor/Wire

    Extra Information

    RATINGS AS PER STANDARDS

    STANDARDSUL 1059
    ApprovalsUL
    Conductor Cross Section Stranded min.24 AWG
    Conductor Cross Section Stranded max.12 AWG
    Rated Voltage 300 V
    Rated Current 24 A
    Tightening Torque 4.5 lb-in

    APPROVALS

    APPROVALS